Joule BetterGrid:
Power Independence at Hyperscale.

Our Joule BetterGrid platform owns the power, water, and fuel stack end-to-end.
Behind-the-meter generation, CHP, and grid-forming batteries deliver AI-ready
resilience on firm equipment orders.

The Power Stack Built for
AI Workloads

Forget waiting for utility interconnections. Our Caterpillar power generation equipment is purchased and scheduled for delivery. Combined Heat and Power (CHP) optimization turns waste heat into cooling capacity—the equivalent of having an extra 1.3GW of electricity without burning additional fuel.

Image

Power Infrastructure

1.5 GW Caterpillar G3520K generation (firm order, delivery March 2026)

415-480V direct-to-rack architecture (no step-down transformers)

Grid-forming BESS: 60-minute full-load ride-through, black-start capable

N+2 redundancy on power and cooling lineup

CHP optimization yields 85% total system efficiency and 1.3 GW equivalent cooling power

Dual 36" Kern River transmission interconnects providing 380,000 Dth/day

Image

Cooling Capabilities

Up to 800kW per rack design capability - Direct-to-chip liquid cooling ready

PUE Target: <1.26 through CHP and altitude advantages

Multiple cooling options - Air, liquid, immersion ready

90% water reduction via CHP. WUE < 0.02 - Advanced recovery and recycling systems

Your Express Lane to
Every Major Market

True redundancy means more than two fiber entrances. Six independent fiber routes from separate providers ensure your data flows regardless of cuts, outages, or carrier issues.

6 diverse fiber routes - Physical path separation

5 Tier-1 carriers on-site - Lumen, Zayo, 
AT&T, Verizon, Google

Multi-terabit capacity - Per route, expandable

Carrier-neutral MMRs - Your choice of providers

100G/400G/800G ready - Future-proof infrastructure

Fiber construction and MMR design by CentraCom

Image
6 diverse fiber routes - Physical path separation

5 Tier-1 carriers on-site - Lumen, Zayo, 
AT&T, Verizon, Google

Multi-terabit capacity - Per route, expandable

Carrier-neutral MMRs - Your choice of providers

100G/400G/800G ready - Future-proof infrastructure

Fiber construction and MMR design by CentraCom

Our Foundation is Built
on Resilience

In Utah’s high-desert environment, seismic and climate risks are comparatively low and well-characterized. The campus pairs strong physical security with resilient, redundantly engineered infrastructure to provide a stable, long-horizon operating environment for your most critical workloads.

  • Perimeter: Multi-layer fencing with intrusion detection
  • Access: Biometric controls at all entry points
  • Surveillance: 24/7 monitoring with AI-powered analytics
  • Response: On-site security with <3-minute response
  • Compliance: SOC 2, HIPAA, PCI-DSS capable design
Image

The Power Partnership Behind the Joule BetterGrid

Our partnership with Caterpillar will deploy the most advanced Combined Heat and Power system in data center history. Waste heat becomes cooling capacity, turning inefficiency into advantage. Developed with Wheeler Power Systems, Utah’s authorized CAT® power dealer and integrator of over a dozen municipal and utility plans.

The Caterpillar Advantage:

1.5GW of generation capacity - equipment in production

Engineered for 99.999% reliability - Proven in mission-critical deployments

46% efficiency before CHP / >90% total with CHP. CHP delivers 1.3 GW of cooling equivalent capacity

Modular scaling - Add capacity as you grow

Materially reduces cooling-tower water through heat-driven absorption

CHP Innovation:

Waste heat capture from generators

Absorption chillers convert heat to cooling

Reduces total energy consumption by 35%

Eliminates cooling tower water waste

Infrastructure Intelligence:
Your Technical Questions Answered

Ready to Deploy Without Grid Delays?

Stop waiting for utility approvals. Start building on infrastructure that's actually ready.